ARIA/ARIA HMI
Station-level operator interface
ARIA HMI · Showcase

The screens of ARIA HMI.

7 main ARIA HMI screens with technical captions. The mockups below are faithful to the actual product — when we show you ARIA HMI live, the same patterns are there.

ARIA HMI on tablet — Station screen, OEE tab with 24-hour availability bar chart and uptime / shift duration / availability KPIs
Screen · 01

OEE · station availability

Station screen OEE tab: availability · performance · quality · OEE up top, 24-hour bar chart with color-coded time bands, uptime / shift duration / availability KPIs on the right. The shift lead sees at a glance whether the station is meeting plan; the operator sees where the shift is losing time.

  • Availability · Performance · Quality · OEE tabs
  • 24-hour bar chart with threshold colors
  • Uptime · shift duration · availability %
  • Shared across the station terminal and tablet
ARIA HMI on tablet — Part traceability tab with product ID and creation/start/end timestamps, CSV export
Screen · 02

Part traceability

Station-level traceability table: product ID, creation timestamp, process start and end for every part that went through the workstation. Time-window filters, pagination on large batches, CSV export to share with quality or line-level traceability.

  • Product ID + creation/start/end timestamps
  • Shift and time-window filters
  • Pagination for large batches
  • CSV export for quality and traceability
aria-hmi · station / stn-02
ARIA HMI/STN-02 · WINDLIVE
Modalità: AUTOAnna B. · operatore
FUSO 1
Velocità
1.420 rpm
Torque
4.21 Nm
FUSO 2
Velocità
1.420 rpm
Torque
4.18 Nm
FUSO 3
Velocità
0 rpm
Torque
FUSO 4
Velocità
1.420 rpm
Torque
4.22 Nm

Ricetta attiva

v.12
STA-V90-EX
Spire target
384
Tensione filo
2.4N

Stato pezzo

lotto L-2026-0457
Spire completate238 / 384
Tempo ciclo08:42 / 18:00
Coppia max4.32 / 6.00 Nm
Pausa ciclo
Stop emergenza
SetupManualeAuto
⚠ Andon▶ Start ciclo
Screen · 03

Station screen

Main view of the machine: status LEDs, PLC commands, real-time values. Every component subscribes to its single OPC UA node — targeted updates, stable frame rates even with hundreds of monitored variables.

  • Targeted per-OPC-UA-node updates
  • Touch-first
  • Buttons write to the PLC
aria-hmi · 3d-viewer / stn-02
ARIA HMI/STN-02 · WINDLIVE
Modalità: MANUALELuca G. · setup
Vista 3D · stazione 02
X 124.8Y 62.4Z 18.2

Jog control

Asse X124.8 mm
0.10 mm
+
Asse Y62.4 mm
0.10 mm
+
Asse Z18.2 mm
0.10 mm
+
Home all
Stop
Reset assiHome
Conferma posizione
Screen · 04

3D viewer + jog control

3D view of the station with live axis feedback. Jog control for manual setup motion, always through the PLC — no bypass of the single source of truth.

  • Real-time 3D view
  • Manual jog
  • Live axis feedback
aria-hmi · alarms / stn-02
ARIA HMI/STN-02 · WINDLIVE
Modalità: AUTOAnna B. · operatore
ALERTA.402Tensione filo fuori range06:24:08ACK
WARNW.118Vibrazione anomala asse Y06:18:42ACK
WARNW.072Cambio bobina raccomandato06:12:01ACK
INFOI.012Reset pressione completato05:48:55ACK
TuttiAttivi (3)Storico
ACK selezionati
Screen · 05

Alarms and ACK

List of active alarms with priority, station context, one-tap ACK. Automatic escalation to the SCADA andon when an alarm crosses its time threshold.

  • One-tap ACK
  • Automatic escalation
  • Severity filter
aria-hmi · recipe / stn-02
ARIA HMI/STN-02 · WINDLIVE
Modalità: SETUPMarco T. · capo turno
Ricette disponibili · 14
  • STA-V90-EX
    v.12 · in linea
    ATTIVA
  • STA-V90-LR
    v.08
  • STA-V120-EX
    v.06
  • STA-V120-LR
    v.04
  • STA-S210
    v.02
Ricetta selezionata
STA-V90-EX
v.12 · pubblicata 2026-04-22 · Marco T.
VALIDATA
ParametriSequenzeLimitiNote
Spire target
384
Tensione filo
2.4N
Velocità nominale
1.420rpm
Coppia max
6.0Nm
Tempo ciclo
18:00min
Cambio bobina ogni
180cicli
Annulla
AnteprimaConferma e attiva
Screen · 06

Recipe selection

On-the-fly model changeover: recipe pick, confirmation, parameter push to the PLC via OPC UA. Core-side validation before activation.

  • Two-tap confirmation
  • Core-side validation
  • Model-change history
aria-hmi · part-status / stn-02
ARIA HMI/STN-02 · WINDLIVE
Modalità: AUTOAnna B. · operatore

Posizione in linea

L-2026-0457 · pezzo 248/250

Parametri raccolti

StazioneParam.ValoreRangeEsito
LOADtorque init4.21 Nm3.8–4.4OK
WINDspire238 / 384targetIN CORSO
WINDtensione filo2.42 N2.2–2.6OK
Lotto
L-2026-0457
Pezzo
#248
ID univoco
P-9817

Anomalie

  • 06:18:42 · vibrazione asse Y oltre soglia (warn)
  • 05:48:55 · reset pressione (info, risolto)
Pezzo precedenteSuccessivo
Apri tracciabilità SCADA
Screen · 07

Part status

Current part status: position along the line, parameters captured so far, flagged anomalies. Useful in setup and troubleshooting.

  • Live position
  • Captured parameters
  • Timestamped anomalies
Demo · pilot · assessment

Want to see ARIA HMI live?

A guided demo shows the same screens on real-plant data.